How to Read a Pump Curve

What is Pump Characteristic Curve Graph?

As the name suggest it is the curve which define the performance characteristics of a pump.

Basically, the pump performance curve is plotted with flow rate along X-Axis and Pressure Head along Y-Axis.

A typical pump curve graph or chart (say for a centrifugal pump) is shown below:

Basic Pump Performance Characteristic Curve

 

How the Curve is Generated?

Pump manufacturer generate the pump performance curve based on the actual performance testing of the pump. For this purpose, the pump is first connected to the pump test station. A typical simplified schematic of the test setup is shown below:

Pump Test Station

 

  • The test starts with the flow control valve in fully closed condition. The flow meter will now show zero, the corresponding pressure head value is noted from the pressure gauge. This way the first point of the curve is plotted in the graph (with flow rate along X and pressure head along Y axis).
  • The flow control valve is opened gradually to get the values of the pressure head for different flow rates.
  • All the generated performance points are then plotted to get the performance curve of the pump.

 

How to read the pump characteristic curve?

It is clear, from the shape of the pump characteristic curve of centrifugal pump shown above, that with the increase in discharge flow rate the discharge pressure decreases.

Know the required flow rate for your system and use the graph to find out the discharge pressure head you will be getting. From the detail version of the curve (shown below), you can also get the values of pump efficiency, NPSH (r) and power against the required flow rate.

 

A more detailed version of the pump performance curves plot is shown below:

 

Detailed Pump Performance Characteristic Curve

 

Apart from the discharge pressure head, the pump efficiency, power, and NPSH (required) is also plotted in the detail characteristic curve.

In the subsequent articles, I will talk about the creation of system resistance curve and the selection procedure of a pump suitable for a particular application.

Shibashis Ghosh

Hi, I am Shibashis, a blogger by passion and an engineer by profession. I have written most of the articles for mechGuru.com. For more than a decades i am closely associated with the engineering design/manufacturing simulation technologies. I am a self taught code hobbyist, presently in love with Python (Open CV / ML / Data Science /AWS -3000+ lines, 400+ hrs. )

This Post Has 2 Comments

  1. hiren

    good

  2. hiren

    best

Leave a Reply

This site uses Akismet to reduce spam. Learn how your comment data is processed.